Bulk Cables - Audio  |  Patch- and Microphone Cable


SOMMER CABLE - SC-SCUBA 14 HIGHFLEX

Construction(2LI2Y0,14mm2)CY
Jacket, diameterPVC 3,8 mm
AWG26
No. of inner conductors2 x 0,14 mm2
Copper strand per conductor18 x 0,10 mm
Conductor insulationPE 1,15 mm
Shieldingcopper braiding with 0.10 mm indiv. strand tin-plated
Shielding factor90 %
Temperature rangemin. -25 C
Temperature rangemax. 70 C
Fire load per m0,09 kWh
Weight per 1 m25 g
Packaging100/500 m roll
Capac. cond./cond. per 1 m65 pF
Capac. cond./shield. per 1 m130 pF
Cond. resistance per 1 km< 135 Ohm
Shield. resistance per 1 km< 30 Ohm
Insulation resist. per 1 km> 1 GOhm
Surge impedanceapprox. 100 Ohm
black red green grey yellow
200-0311200-0313200-0314200-0316200-0317



SOMMER CABLE - SC-GOBLIN

Construction(2LI2Y0.14mm2)(ST)DY
Jacket, diameterPVC 4,6 mm
AWG26
No. of inner conductors2 x 0,14 mm2
Copper strand per conductor18 x 0,10 mm
Conductor insulationPE 1,05 mm
Shieldingcopper spiral sleeve tin-plated + metalic fleece
Shielding factor100 %
Temperature rangemin. -25 C
Temperature rangemax. 70 C
Fire load per m0,10 kWh
Weight per 1 m27 g
Packaging100 m roll
Capac. cond./cond. per 1 m65 pF
Capac. cond./shield. per 1 m120 pF
Cond. resistance per 1 km< 140 Ohm
Shield. resistance per 1 km30 Ohm
Insulat. resistance per 1 km> 200 MOhm
white black blue red icy gray
200-0350NE200-0351200-0352200-0353200-0356



SOMMER CABLE - SC-PEACOCK MKII

Construction{2(2LI2Y0,22mm2)DY}Y
Jacket, outer dimensionPVC 4,5 x 9,2 mm
AWG24
No. of inner conductors2 x 2 x 0,22 mm2
Copper strand per conductor28 x 0,10 mm
Conductor insulationFoam/skin-PE 1,3 mm
Shieldingcopper spiral shielding
Shielding factor95 %
Temperature rangemin. -30 C
Temperature rangemax. 70 C
Fire load per m0,18 kWh
Weight per 1 m49 g
Packaging100 m roll
Capac. cond./cond. per 1 m70 pF
Capac. cond./shield. per 1 m125 pF
Cond. resistance per 1 km< 90 Ohm
Shield. resistance per 1 km36 Ohm
Insulat. resistance per 1 km> 500 MOhm
Surge impedance per 1 km110 Ohm
black
200-0551



SOMMER CABLE - SC-CICADA SO-D14

Construction(2LI2Y0.14mm2)DY
Jacket, diameterPUR Master Blend 2,6 mm
AWG26
No. of inner conductors2 x 0,14 mm2
Copper strand per conductor18 x 0,10 mm
Cond. insulationPE 0,90 mm
Shieldingcopper spiral shielding + filler strand, tin-plated (0.22 mm2)
Shielding factor95 %
Temperature rangemin. -30 C
Temperature rangemax. 70 C
Fire load per m0,08 kWh
Weight per 1 m13 g
Packaging100 m roll
Capac. cond./cond. per 1 m65 pF
Capac. cond./shield. per 1 m120 pF
Cond. resistance per 1 km< 148 Ohm
Shield. resistance per 1 km30 Ohm
Insulation resist. per 1 km> 1 GOhm
black
200-0451